Handrail Height Regulations UK: What the Building Rules Say

In England, Approved Document K says the top of a stair handrail should sit 900mm to 1000mm above the pitch line or floor. Guarding at the edges of landings and floors is a separate measurement, and the height depends on the building type. These are guidance figures for England, so confirm your design with your designer or building control before you order.

Approved Document K, which supports Part K of the Building Regulations 2010, covers protection from falling, collision and impact. If you are planning a steel handrail, our handrail standards and fittings page shows the styles and fittings South West Steel Supplies works with. The rest of this guide covers what the document says, where handrails and guarding differ, and what to check first.

Handrail Height on Stairs: The 900mm to 1000mm Rule and Building Regulations

For all buildings, Approved Document K positions the top of the handrail 900mm to 1000mm from the pitch line or the floor. The pitch line is the sloping line that connects the nosings of the treads.

Two other points from the same part of the document are worth knowing:

  • The handrail may form the top of the guarding, provided the heights can be matched.
  • Stairs 1000mm or wider need a handrail on both sides.

If you are drawing this out for a designer, describe the stair in words first: the pitch line, the handrail above it, and the guarding at the open edge. The Approved Document includes diagrams that show the exact arrangement.

Handrail Height Versus Guarding Height

A handrail is there for support. Guarding is there to stop a fall. They are different parts of a stair or landing, and each has its own height in the Approved Document.

The guarding heights below come from the table in Diagram 3.1. They are the heights given in the Approved Document for each building type.

Building type Stairs and flights Landings, floor edges and other areas
Single family dwellings 900mm on stairs, landings, ramps and internal floor edges 1100mm for external balconies and roof edges
Factories and warehouses (light traffic) 900mm on stairs and ramps 1100mm on landings and floor edges
Residential, institutional, educational, office and public buildings 900mm for flights 1100mm otherwise
Retail 900mm for flights 1100mm otherwise

The table covers only the building types listed above. For anything else, check the Approved Document directly or ask your building control body.

Stair Handrail Requirements for Buildings Other Than Dwellings

Most retailer guides focus on domestic staircases. Commercial and industrial stairs, platforms and landings follow slightly different rules, set out in paragraphs 1.35 and 1.36 and Diagram 1.12 of Approved Document K.

The main points are:

  • Continuous handrails on each side of flights and landings, projecting 300mm minimum beyond the flight ends.
  • A handrail top height of 900mm to 1000mm above the pitch line, and 900mm to 1100mm on landings.
  • Handrails that do not project into an access route.
  • A handrail that contrasts visually with the background, with a slip-resistant surface and an end finish that reduces clothing catching.
  • Where there is full-height structural guarding and a second lower handrail is provided, the top of that lower rail is 600mm above the pitch line.

See the Approved Document diagram for the exact arrangement on your stair.

Guarding Openings, Laminated Safety Glass, and the 100mm Rule

Height is only half of the guarding question. The gaps matter too. In buildings that may be used by children under five, a 100mm sphere should not pass through any opening in the guarding, and horizontal rails should be avoided.

BS 6180 is the code of practice for barriers in and about buildings, and Approved Document K refers to it for the design of barriers and infill panels. We have not listed any barrier loadings here. Your designer or engineer confirms those.

Workplace Rules: Handrails Under HSE Guidance and Approved Document

Workplaces have separate duties that sit alongside building control. HSE guidance on the Workplace (Health, Safety and Welfare) Regulations 1992 says a secure and substantial handrail should be provided on at least one side of every staircase, except where it would obstruct a traffic route.

That guidance is published in the HSE’s L24 document. Check the current guidance on the HSE website, or ask your health and safety adviser how it applies to your premises.

Steel Handrail Standards, Fittings and Getting the Specification Right

Once you know the heights, the next question is what to build with. South West Steel Supplies offers our steel handrail range in these forms:

  • Flat base handrail standards
  • Side palm handrail standards
  • Raked handrail standards
  • Handrail fittings to go with them

We also offer processing, including plasma cutting, drilling, profiling, punching, shearing and folding. For the build method, our post on tube clamps vs welded handrail compares the two approaches, and our FastClamp tube clamps page covers the clamp option. If the rail will be made from tube, see our guide to galvanised steel tube.

Our products are UKCA/CE approved materials, but we do not claim that any product meets Part K. Your designer, engineer or building control confirms the specification, load rating and compliance for your job.

If your platform or walkway also needs a walking surface, see when to use walkway mesh for your business premises.

Check Before You Order

Before you commit to a design for steel handrail standards, run through this list:

  1. Confirm the building type, because dwellings and other buildings follow different rules.
  2. Measure the flight width, since stairs 1000mm or wider need a handrail on both sides.
  3. Decide whether you need a handrail on both sides, and whether it must be continuous.
  4. Confirm the guarding height for each part of the stair, landing or edge.
  5. Check local rules. The figures here are for England. Wales publishes its own Part K, so check the current Welsh guidance if your site is in Wales.

Ask your designer, engineer or building control to confirm each point in writing where you can.

Planning a Steel Handrail?

If you are researching handrail heights with a view to a steel handrail, steel handrail standards and fittings show how South West Steel Supplies approaches it. We give same-day quotations and deliver across the South West. Send us your drawings or call 01275 814178 to request a quote on handrail standards.

Key Takeaways

  • Approved Document K sets the top of a stair handrail 900mm to 1000mm from the pitch line or floor, in all buildings.
  • Stairs 1000mm or wider need a handrail on both sides.
  • Guarding height differs from handrail height: for example 900mm on flights and 1100mm on landings and edges in factories and warehouses (light traffic).
  • Where children under five may use a building, a 100mm sphere should not pass through guarding openings.
  • These figures are for England; confirm with your designer, engineer or building control and check Welsh guidance if the site is in Wales.

Frequently Asked Questions

What is the standard height of a handrail in the UK?

Under Approved Document K in England, the top of a stair handrail sits 900mm to 1000mm from the pitch line or floor. Guarding is a separate measurement and may be higher. Confirm the figures for your project with building control.

Do stairs need a handrail on both sides?

Where a stair is 1000mm or wider, Approved Document K calls for a handrail on both sides. For buildings other than dwellings, the document describes continuous handrails on each side of flights and landings, shown in its diagram. Always check the arrangement with your designer.

How high should a landing or balcony guard be?

It depends on the building type. In a single family dwelling, the figure is 900mm for internal elements and 1100mm for external balconies and roof edges. In factories and warehouses with light traffic, it is 1100mm on landings and floor edges. Confirm the height with building control.

Useful Resources

Menu

Get a Quote

    ×

    Ask a Question

    [gravityform id=”2″ title=”false” description=”false”]

    ×